your safety is our first priority


Fire alarm control panel

Product features:

LPCB and CPR approval.

324 addresses for one loop or 510 addresses for two loops.

4.3’’ color screen LCD, resolution of 480×272.

Zone indication and control panel for 32 zones gives a quick indication of the location of an alarm.

Record capacity of 1000 historical events with date/time stamp.

Integral power supply and battery.

Integral printer.

An standalone programmable conventional sounder circuit output.

Flexible and intuitive cause and effect programming on front of panel.

Output module manual start/stop facilitates the commissioning and operating.

It supports the detector/module testing individually.

USB port makes the load and save of configuration data or historical data convenient for system commissioning and maintenance.

Networkable: CAN bus for interconnection of up to 20 FACPs and Ethernet for up to 255 FACPs.



Point-type Photoelectric Smoke Detector

Product features:

LPCB & CPR approval.

It supports soft addressing and rewriting the address via coder in situ.

Within a single-chip microcomputer, it can process the sampling data in real-time, save the latest 144 historical data and realize a curve tracing for the field situation.

It supports temperature, humidity and dust accumulation drift compensation and sensor fault inspection (fault reporting to fire alarm control panel).

Non-polarity, two-wire bus connection that ensures convenient installation and maintenance.

Designed with an upper cover and a lower cover and installed on a detector base, it can be installed, commissioned and maintained conveniently.

Built-in remote indicator output terminal, the output signal drives remote indicator light when fire alarm.



Point-type Heat Fire Detector

Product features:

LPCB and CPR approval

It supports soft addressing and rewriting the address via coder in situ.

Within a single-chip microcomputer, it can collect real-time data and then process it to realize a curve tracing for the field situation.

It supports temperature compensation and a sensor fault detection(fault reporting to the fire alarm control panel).

Non-polarity, two-wire bus wiring that ensures convenient installation and maintenance.

Designed with an upper cover and a lower cover and installed on a detector base, it can be installed, commissioned and maintained conveniently and do not distinguish the connection line.

Built-in remote indicator output terminal, the output signal drives remote indicator light when fire alarm.



Manual Call Point

Product Features:

LPCB and CPR approval.

Semi-flush or surface mount.

Lever reusable (non-glass break).

LED indicator.

Support non-polarity, complete soft addressing in situ.

Designed with passive output contacts to control other external equipment directly via an intermediate relay.



I/O module

Product Feature:

LPCB approval.

Semi-flush or surface mount.

Lever reusable (non-glass break).

LED indicator.

Full soft addressing, and rewriting through CODER-9001 encoder in site.



Short circuit isolator

Product Features:

LPCB & CPR approval.

In the event of a short circuit it isolates faulty parts of the loop.

Automatically resetting once the fault has been cleared.

LED lights indicate status.



Addressable Sounder visual indicator

Product Features:

Meet both EN54-3 and EN54-23.

Designed with an upper cover and a lower cover and installed on an independent base, it can be installed,debugged and maintained conveniently.

Suitable for wall and ceiling mount application Providing 16 tones.

Highly efficient LED technology and specially designed lens Light output synchronization.



Intelligent Sounder Beacon Base

Product Features:

Meet EN54-3.

It is installed by rotating, it can be installed conveniently and reliably.

It uses multiple super bright red LEDs as light sources for visual display, ensuring a striking display effect.

Set the detector base and Sounder beacon as a whole, it can be equipped with A9030T smoke detector and A9020T heat detector, single point connection for detector, sounder and LED beacon (saving on both time and installation costs) , debugged and maintained conveniently.

Intelligent Sounder Beacon Base is addressable , low power consumption and loop powered to reduce installation cost. The Intelligent Sounder Beacon Base can be used a stand-alone device or with a detector. The detector can be mounted directly on the base.